4 Pack ASCO 1/2" NPT Red Hat Series 12V DC 2 Way Normally Closed solenoid valve with 230 PSI Max Pressure. Compact Size with High Air Flow. Inlet & Outlet Ports are NPT Threads.
ASCO brand 1/2" NPT 12V DC 2 Way Normally closed valve with 230 PSI Max, High Air Flow. (P/N SC8238T405)
NOTE: NPT Threads will always measure bigger than the actual valve threaded inlet or outlet, when measured with tape.
Specifications & Features:
- 12V DC Normally Closed 2 Way 1/2" NPT Threads. Does not come with any valve mount brackets.
- Brass body with inlet & outlet (Air Flow Arrow) marked at the bottom of valves.
- Low AMP draw, with 6.9 Watt solenoid coil, Pilot operated valves with water tight enclosure.
- 230 PSI inlet pressure capability. 19/32" Orifice DIA (.5938",15MM) with 2.89 Cv Flow.
- DIN Connector connections (DIN Connector sold separately, Not Included with Valve)
- Compact Size for tight locations.
- High Ambient temperature rating 15- 176 Degree F, for under hood applications.
- 16 or 18 AWG Gauge wire for power and ground connections. (Applicable)
- Can be used for Air, Inert Gas, Water, light oil
- 5 PSI Minimum pressure required to open the valve.
NOTE: Please note that Maximum inlet pressure will depend upon the type of application as well as for different types of media (Air, Gas or water etc.). These valves are for general use only. Cannot be used with hot water or Fuel gas etc.
|
|
|